The 651 RF Admittance Single Point Level Switch is a level control which
uses dielectric constant and conductivity to detect the level of liquids,
slurries, granulars, and solids. When used with any of the RF Probes,
it will provide accurate switching for level processes.
The control features a fail-safe switch which reverses the operation of
the relay. An LED inside the housing lights when the process is touching
the probe. A sensitivity adjustment inside the control allows the user to
increase or decrease sensitivity as needed. Optional time delay feature
will delay switching on or off from 0 to 60 seconds.
651 RF Admittance
Single Point Level Switch
General Instructions
Registered Quality System to ISO 9001
Design and
specifications are
subject to change
without notice.
For latest revision, go to
www.sorinc.com
NOTE: If you suspect that a product is defective, contact the factory or the
SOR
®
Representative in your area for a return authorization number (RMA).
This product should only be installed by trained and competent personnel.
Table of Contents
Pre-Installation I/O Test and Calibration ....1
Installation ....................................... 3
Electrical Connections .........................4
RF Probe Grounding Scheme .................5
Fail-Safe Mode ..................................6
Circuit Board Replacement ....................7
Sensor Replacement ...........................7
Control Drawings ............................ 8-9
Troubleshooting ............................... 10
Dimensions ................................ 11-12
Pre-Installation I/O Test and Calibration
Remove instrument from shipping box and visually inspect for obvious
physical damage. Report any shipping damage to the carrier. Report
any internal discrepancies to the factory representative in your area.
Record the serial number from the nameplate should conversation
with the factory be necessary.
Remove housing cover.
Place instrument on an insulated surface or support so sensor does not touch a
conductive surface.
Ensure area is safe and observe normal precautions for exposed and powered PC board.
Apply proper line power per page 4, and observe LED. (See
)
h
g
)
.
o
us
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - Single Point Level Switch

Form 830 (03.13) ©SOR Inc. 1/12The 651 RF Admittance Single Point Level Switch is a level control which uses dielectric constant and conductivity to

Strona 2

10/12Form 830 (03.13) ©SOR Inc. TroubleshootingSymptom/Problem Possible Cause Corrective ActionLED will not illuminate, even at maxmum sensitivity set

Strona 3 - Installation

Form 830 (03.13) ©SOR Inc. 11/12DimensionsA LENGTH (PER MODEL NUMBER)116.74.5996.03.78BC19.10.75(INACTIVE SHEATH ONLY)DINACTIVE SHEATH LENGTH(PER MOD

Strona 4 - Electrical Connections

12/12Form 830 (03.13) ©SOR Inc. 14685 West 105th Street, Lenexa, KS 66215  913-888-2630  800-676-6794 USA  Fax 913-888-0767Registered Quality

Strona 5 - SOR RF Probe Grounding Scheme

2/12Form 830 (03.13) ©SOR Inc.  Turn sensitivity adjustment clockwise (25 turns) to increase sensitivity until the LED illuminates indicating that t

Strona 6 - Fail-Safe Mode

Form 830 (03.13) ©SOR Inc. 3/12InstallationOilWaterStandard con guration is a 3/4” NPT(M) pipe nipple that threads into a 3/4” NPT(F) ves-sel nozzle

Strona 7 - Circuit Board Replacement

4/12Form 830 (03.13) ©SOR Inc. Electrical ConnectionsElectrical power must be disconnected from explosion-proof models before the cover is removed. Fa

Strona 8 - Control Drawing

Form 830 (03.13) ©SOR Inc. 5/12120 VAC (651K7)Remove cover. Observe all applicable electrical codes and recognized wiring practices. Remove two

Strona 9

6/12Form 830 (03.13) ©SOR Inc. Fail-Safe ModeThe fail-safe mode on either rising or falling level can be easily changed in the field. See procedure an

Strona 10 - Troubleshooting

Form 830 (03.13) ©SOR Inc. 7/12 Disconnect power to the unit. Remove the housing cover. Remove two mounting screws and slide out PC board to ex

Strona 11 - Dimensions

8/12Form 830 (03.13) ©SOR Inc. Control Drawing

Strona 12

Form 830 (03.13) ©SOR Inc. 9/12Control Drawing